Zendure Solarflow 800 Pro
Usage areas
- Solar production
- Battery
Parameters
| Name | Description | Value | Level |
|---|---|---|---|
host | IP address or hostname | optional | |
capacity [kWh] | Battery capacity | optional | |
minsoc [%] | Minimum charge Lower limit when discharging the battery in normal operation | optional | |
maxsoc [%] | Maximum charge Upper limit when charging the battery from the grid | optional | |
maxacpower [W] | Maximum AC power of the hybrid inverter | advanced | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | advanced | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | advanced | |
cache | Cache Time interval for data refresh | advanced |
Configuration example for evcc.yaml
If you don't want to configure via the UI, you can alternatively use this YAML block.
meters: - name: my_pv type: template template: zendure-solarflow-pro usage: pv host: 192.0.2.2 # IP address or hostname maxacpower: 800 # Maximum AC power of the hybrid inverter (W), optional cache: 1s # Cache, Time interval for data refresh (optional)meters: - name: my_battery type: template template: zendure-solarflow-pro usage: battery host: 192.0.2.2 # IP address or hostname capacity: 1.92 # Battery capacity (kWh), optional minsoc: 25 # Minimum charge (%), Lower limit when discharging the battery in normal operation (optional) maxsoc: 95 # Maximum charge (%), Upper limit when charging the battery from the grid (optional) maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional) cache: 1s # Cache, Time interval for data refresh (optional)