Skip to content
EN | DE

Victron Energy

For grid usage, a grid meter VRM instance is require to enabled load management.

Supported features

  • Battery control: External control of home battery charging and discharging via evcc.

Usage areas

  • Grid meter
  • Solar production
  • Battery

Parameters

NameDescriptionValueLevel
hostIP address or hostname
Example: 192.0.2.2
optional
portPort
Default: 502
optional
meteridGrid meter VRM instance

Can be read out in VRM portal or via remoteUI.

optional
capacity [kWh]Battery capacity
Example: 50
optional
minsoc [%]Minimum charge

Lower limit when discharging the battery in normal operation

Example: 25
optional
maxsoc [%]Maximum charge

Upper limit when charging the battery from the grid

Example: 95
optional
maxacpower [W]Maximum AC power of the hybrid inverter
Default: 0
Example: 5000
advanced
maxchargepower [W]Maximum charge power

For forced charging of the battery.

advanced
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

meters:
- name: my_grid
type: template
template: victron-energy
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 502 # Port, optional
meterid: # Grid meter VRM instance, Can be read out in VRM portal or via remoteUI. (optional)
meters:
- name: my_pv
type: template
template: victron-energy
usage: pv
host: 192.0.2.2 # IP address or hostname
port: 502 # Port, optional
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
meters:
- name: my_battery
type: template
template: victron-energy
usage: battery
host: 192.0.2.2 # IP address or hostname
port: 502 # Port, optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 25 # Minimum charge (%), Lower limit when discharging the battery in normal operation (optional)
maxsoc: 95 # Maximum charge (%), Upper limit when charging the battery from the grid (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)