SolarEdge Hybrid Inverter
Only one system can and may have a Modbus TCP connection to the inverter at the same time! For optional battery control, StorageConf_CtrlMode (0xE004) must be set to 4 "Remote".
Supported features
- Battery control: External control of home battery charging and discharging via evcc.
Usage areas
- Grid meter
- Solar production
- Battery
Parameters
Modbus
| Name | Description | Value | Level |
|---|---|---|---|
id | Modbus ID | int | required |
device | Device name USB-RS485 adapter | required | |
baudrate | Baudrate | required | |
comset | ComSet Communication parameter for the adapter | required | |
host | IP address or hostname | required | |
port | Port | int | required |
capacity [kWh] | Battery capacity | optional | |
minsoc [%] | Minimum charge Lower limit when discharging the battery in normal operation | optional | |
maxsoc [%] | Maximum charge Upper limit when charging the battery from the grid | optional | |
maxacpower [W] | Maximum AC power of the hybrid inverter | advanced | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | advanced | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | advanced | |
watchdog | Watchdog | advanced |
Configuration example for evcc.yaml
If you don't want to configure via the UI, you can alternatively use this YAML block.
meters: - name: my_grid type: template template: solaredge-hybrid usage: grid
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 1502 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 1502 # Port watchdog: 60s # Watchdog, optionalmeters: - name: my_pv type: template template: solaredge-hybrid usage: pv
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 1502 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 1502 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional watchdog: 60s # Watchdog, optionalmeters: - name: my_battery type: template template: solaredge-hybrid usage: battery
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 1502 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 1502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 25 # Minimum charge (%), Lower limit when discharging the battery in normal operation (optional) maxsoc: 95 # Maximum charge (%), Upper limit when charging the battery from the grid (optional) maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: 5000 # Maximum discharge power (W), Maximum discharge power of the storage. (optional) watchdog: 60s # Watchdog, optional