Kostal Plenticore Hybrid, incl. grid charging of the house battery
Only a single system may access the inverter! For active battery control, the feature external battery control via modbus must be activated using installer access. Can basically be used for various inverter generations (G1/G2/G3). The function for grid charging the battery is available using this template, but is currently incompatible with some older inverters - test carefully! see also https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore
Supported features
- Battery control: External control of home battery charging and discharging via evcc.
Usage areas
- Solar production
- Battery
Parameters
| Name | Description | Value | Level |
|---|---|---|---|
id | Modbus ID | int | required |
host | IP address or hostname | required | |
port | Port | int | required |
capacity [kWh] | Battery capacity | optional | |
minsoc [%] | Minimum charge Lower limit when discharging the battery in normal operation | optional | |
maxsoc [%] | Maximum charge Upper limit when charging the battery from the grid | optional | |
endianness | Endianness (Little/Big) | advanced | |
maxacpower [W] | Maximum AC power of the hybrid inverter | advanced | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | advanced | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | advanced | |
watchdog | Watchdog | advanced |
Configuration example for evcc.yaml
If you don't want to configure via the UI, you can alternatively use this YAML block.
meters: - name: my_pv type: template template: kostal-plenticore-gen2 usage: pv
# Modbus TCP modbus: tcpip id: 71 host: # Hostname port: 1502 # Port endianness: little # Endianness (Little/Big), [little, big] (optional) maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional watchdog: 60s # Watchdog, optionalmeters: - name: my_battery type: template template: kostal-plenticore-gen2 usage: battery
# Modbus TCP modbus: tcpip id: 71 host: # Hostname port: 1502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 25 # Minimum charge (%), Lower limit when discharging the battery in normal operation (optional) maxsoc: 95 # Maximum charge (%), Upper limit when charging the battery from the grid (optional) endianness: little # Endianness (Little/Big), [little, big] (optional) maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional) watchdog: 60s # Watchdog, optional