IAMMETER WEM3080T/WEM3046T/WEM3050T

3-phase meters (WEM3080T/WEM3046T/WEM3050T) require Net Metering Mode (NEM) to be enabled. See https://www.iammeter.com/newsshow/net-energy-metering

Usage areas

  • Grid meter
  • Solar production
  • Charger meter

Parameters

NameDescriptionValueLevel
hostIP address or hostname
Example: 192.0.2.2
optional
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

meters:
- name: my_grid
type: template
template: iammeter
usage: grid
host: 192.0.2.2 # IP address or hostname
meters:
- name: my_pv
type: template
template: iammeter
usage: pv
host: 192.0.2.2 # IP address or hostname
meters:
- name: my_charger
type: template
template: iammeter
usage: charge
host: 192.0.2.2 # IP address or hostname