Skip to content
EN | DE

Enphase IQ Envoy

Usage areas

  • Grid meter
  • Solar production
  • Battery

Parameters

NameDescriptionValueLevel
hostIP address or hostname
Example: 192.0.2.2
optional
tokenToken

Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: enphase.com

optional
capacity [kWh]Battery capacity
Example: 50
optional
minsoc [%]Minimum charge

Lower limit when discharging the battery in normal operation

Example: 25
optional
maxsoc [%]Maximum charge

Upper limit when charging the battery from the grid

Example: 95
optional
schemaSchema
Default: https
advanced
battery_typeEnphase Battery Type (AC or IQ)

Select 'iq' for new Enphase IQ Batteries. Leave at default 'ac' for older generation AC Batteries.

Default: ac
advanced
maxchargepower [W]Maximum charge power

For forced charging of the battery.

advanced
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

advanced
cacheCache

Time interval for data refresh

Default: 1s
Example: 5m
advanced
timeoutTimeout
Default: 10s
Example: 10s
advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

meters:
- name: my_grid
type: template
template: enphase
usage: grid
host: 192.0.2.2 # IP address or hostname
token: # Token, Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: [enphase.com](https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication) (optional)
schema: https # Schema, [https, http] (optional)
battery_type: ac # Enphase Battery Type (AC or IQ), Select 'iq' for new Enphase IQ Batteries. Leave at default 'ac' for older generation AC Batteries. [ac, iq] (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional
meters:
- name: my_pv
type: template
template: enphase
usage: pv
host: 192.0.2.2 # IP address or hostname
token: # Token, Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: [enphase.com](https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication) (optional)
schema: https # Schema, [https, http] (optional)
battery_type: ac # Enphase Battery Type (AC or IQ), Select 'iq' for new Enphase IQ Batteries. Leave at default 'ac' for older generation AC Batteries. [ac, iq] (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional
meters:
- name: my_battery
type: template
template: enphase
usage: battery
host: 192.0.2.2 # IP address or hostname
token: # Token, Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: [enphase.com](https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication) (optional)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 25 # Minimum charge (%), Lower limit when discharging the battery in normal operation (optional)
maxsoc: 95 # Maximum charge (%), Upper limit when charging the battery from the grid (optional)
schema: https # Schema, [https, http] (optional)
battery_type: ac # Enphase Battery Type (AC or IQ), Select 'iq' for new Enphase IQ Batteries. Leave at default 'ac' for older generation AC Batteries. [ac, iq] (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional