Skip to content
EN | DE

Roth ThermoAura

For heatpumps with Luxtronik 2.1 controller. Uses modbus-tcp. Requires software v3.90.3 or later. Enable via SERVICE, Systemsteuerung, Konnektivität, Smart-Home-Interface.

Parameters

NameDescriptionValueLevel
idModbus ID
Default: 1
intrequired
hostIP address or hostname
Example: 192.0.2.2
required
portPort
Default: 502
intrequired
timeoutTimeout
Default: 10s
Example: 10s
optional
heatoffset [K]Heating temperature boost
Default: 0.0
Example: 2.0
optional
wwoffset [K]Hot water temperature boost

Temperature boost offset for hot water. Possibly increases wear on compressor.

Default: 0.0
Example: 8.5
advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

chargers:
- name: my_heating
type: template
template: luxtronik
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
timeout: 10s # Timeout, optional
heatoffset: 0.0 # Heating temperature boost (K), optional
wwoffset: 0.0 # Hot water temperature boost (K), Temperature boost offset for hot water. Possibly increases wear on compressor. (optional)