ChargeLine Business Wallbox
Chargers with firmware version 1.6 and onwards support Modbus TCP via port 502. The Modbus server needs to be enabled via the charger web interface. Ensure that smart charging strategies are disabled and set to Default.
Supported features
- mA regulation: Finer charging current regulation (mA instead of A) for better solar surplus use.
- 1P/3P: Automatic phase switching. Useful for solar surplus charging.
- Built-in meter: Support for an integrated meter. Availability may vary between models.
Parameters
| Name | Description | Value | Level |
|---|---|---|---|
id | Modbus ID | int | required |
host | IP address or hostname | required | |
port | Port | int | required |
Configuration example for evcc.yaml
If you don't want to configure via the UI, you can alternatively use this YAML block.
chargers: - name: my_charger type: template template: peblar
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port