Amperfied Wallbox Energy Control

Please read the wiring and configuration manual carefully. All boxes must be configured for external control in follower mode (DIP S5/4 OFF). Each box needs an individual Modbus ID (DIP S4). Ensure correct RS485 cabling including bus termination (DIP S6/2).

Supported features

  • mA regulation: Finer charging current regulation (mA instead of A) for better solar surplus use.
  • Built-in meter: Support for an integrated meter. Availability may vary between models.

Parameters

Modbus
NameDescriptionValueLevel
idModbus ID
Default: 1
intrequired
deviceDevice name

USB-RS485 adapter

Example: /dev/ttyUSB0
required
baudrateBaudrate
Default: 9600
required
comsetComSet

Communication parameter for the adapter

Default: 8N1
required
hostIP address or hostname
Example: 192.0.2.2
required
portPort
Default: 502
intrequired
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

chargers:
- name: my_charger
type: template
template: heidelberg
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8E1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: # Hostname
port: 502 # Port