Alfen Eve
The "Active load balancing" license is required for external Modbus control of the charger. Enable "Active Load Balancing" and select "Energy Management System" as Data Source in the configuration. It is recommended to set "ValidityTime" ("TCP/IP EMS" menu) to 300s. When using "Double" charger both loadpoints need to be added. The the first port (or single) is accessable on ID 1, second port on ID 2.
Supported features
- mA regulation: Finer charging current regulation (mA instead of A) for better solar surplus use.
- 1P/3P: Automatic phase switching. Useful for solar surplus charging.
- Built-in meter: Support for an integrated meter. Availability may vary between models.
Parameters
| Name | Description | Value | Level |
|---|---|---|---|
id | Modbus ID | int | required |
host | IP address or hostname | required | |
port | Port | int | required |
Configuration example for evcc.yaml
If you don't want to configure via the UI, you can alternatively use this YAML block.
chargers: - name: my_charger type: template template: alfen
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port