Alfen Eve

The "Active load balancing" license is required for external Modbus control of the charger. Enable "Active Load Balancing" and select "Energy Management System" as Data Source in the configuration. It is recommended to set "ValidityTime" ("TCP/IP EMS" menu) to 300s. When using "Double" charger both loadpoints need to be added. The the first port (or single) is accessable on ID 1, second port on ID 2.

Supported features

  • mA regulation: Finer charging current regulation (mA instead of A) for better solar surplus use.
  • 1P/3P: Automatic phase switching. Useful for solar surplus charging.
  • Built-in meter: Support for an integrated meter. Availability may vary between models.

Parameters

NameDescriptionValueLevel
idModbus ID
Default: 1
intrequired
hostIP address or hostname
Example: 192.0.2.2
required
portPort
Default: 502
intrequired
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

chargers:
- name: my_charger
type: template
template: alfen
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port